| D&D TECHINCAL SPECIFICATIONS |
Detection Method
|
2 matching dual elements/optics - Passive infrared |
| Detection Speed |
0.5 to 6 ft/sec (0.15 to 1.8 m/sec) |
| Sensitivity |
2°F at 3 ft/sec (1.1°C at 0.9 m/sec) |
| Warm up period |
3 sec |
| Alarm period |
2 sec |
| Power input |
7.8-16 VDC |
| Current draw |
8.4 mA between 7.8 and 16 VDC |
| Alarm output |
N.C 28 VDC 0.1A with 10 Ohm series protection resistor |
| Tamper switch |
N.C 28 VDC 0.1A open when cover is removed |
Automatic Temperature compensation |
Constant gain at -4°F to +158°F (-20°C to +70°C) |
| Humidity |
Up to 95% R.H. non-condensing |
| RFI protection |
30V/m 10-1000 MHz |
| EMI protection |
50,000 V of electrical interference from lightning or power through |
| Operating Temperature |
-4°F to +158°F (-20°C to +70°C) |
| Visible light protection |
Stable against halogen light at 3.3 ft (1m) |
| Lenses |
Wide angle, long range, vertical barrier (curtain) - Interchangeable |
| Dimensions |
5.4" (137 mm) x 3.4" (85 mm) x 1.7" (43 mm) |
| Weight |
5.32 oz (150gr.) |